blog:20231221

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
blog:20231221 [2023/12/21 14:04] Roy Proutyblog:20231221 [2023/12/21 16:54] (current) Roy Prouty
Line 19: Line 19:
 Modified Table for Calibration Frames only Modified Table for Calibration Frames only
 ^ Time Observed  ^  Int Time [ms] ^  Scope ^ Purpose ^ Notes^ ^ Time Observed  ^  Int Time [ms] ^  Scope ^ Purpose ^ Notes^
-|  20231221T14  |  0.032     | None| Calibration Study |Cooler set to -10|+|  20231221T14  | 5x 0.032     | None| Calibration Study |2600;G0,B0,T-10| 
 +|  20231221T14  | 5x 0.100     | None| Calibration Study |2600;G0,B0,T-10| 
 +|  20231221T14  | 5x 0.500     | None| Calibration Study |2600;G0,B0,T-10| 
 +|  20231221T14  | 5x 1.000     | None| Calibration Study |2600;G0,B0,T-10| 
 +|  20231221T14  | 5x 5.000     | None| Calibration Study |2600;G0,B0,T-10| 
 +|  20231221T14  | 5x 10.000    | None| Calibration Study |2600;G0,B0,T-10| 
 +|  20231221T14  | 5x 50.000    | None| Calibration Study |2600;G0,B0,T-10| 
 +|  20231221T14  | 5x 100.000   | None| Calibration Study |2600;G0,B0,T-10| 
 +|  20231221T14  | 5x 1 000.000 | None| Calibration Study |2600;G0,B0,T-10| 
 +|  20231221T14  | 5x 5 000.000 | None| Calibration Study |2600;G0,B0,T-10| 
 +|  20231221T14  | 5x 10 000.000| None| Calibration Study |2600;G0,B0,T-10| 
 +|  20231221T14  | 5x 50 000.000| None| Calibration Study |2600;G0,B0,T-10| 
 +|  20231221T14  | 5x 0.032     | None| Calibration Study |2600;G0,B0,T0| 
 +|  20231221T14  | 5x 0.100     | None| Calibration Study |2600;G0,B0,T0| 
 +|  20231221T14  | 5x 0.500     | None| Calibration Study |2600;G0,B0,T0| 
 +|  20231221T14  | 5x 1.000     | None| Calibration Study |2600;G0,B0,T0| 
 +|  20231221T14  | 5x 5.000     | None| Calibration Study |2600;G0,B0,T0| 
 +|  20231221T14  | 5x 10.000    | None| Calibration Study |2600;G0,B0,T0| 
 +|  20231221T14  | 5x 50.000    | None| Calibration Study |2600;G0,B0,T0| 
 +|  20231221T14  | 5x 100.000   | None| Calibration Study |2600;G0,B0,T0| 
 +|  20231221T14  | 5x 1 000.000 | None| Calibration Study |2600;G0,B0,T0| 
 +|  20231221T14  | 5x 5 000.000 | None| Calibration Study |2600;G0,B0,T0| 
 +|  20231221T14  | 5x 10 000.000| None| Calibration Study |2600;G0,B0,T0| 
 +|  20231221T14  | 5x 50 000.000| None| Calibration Study |2600;G0,B0,T0| 
 +|  20231221T14  | 5x 0.032     | None| Calibration Study |2600;G1,B0,T-10| 
 +|  20231221T14  | 5x 0.100     | None| Calibration Study |2600;G1,B0,T-10| 
 +|  20231221T14  | 5x 0.500     | None| Calibration Study |2600;G1,B0,T-10| 
 +|  20231221T14  | 5x 1.000     | None| Calibration Study |2600;G1,B0,T-10| 
 +|  20231221T14  | 5x 5.000     | None| Calibration Study |2600;G1,B0,T-10| 
 +|  20231221T14  | 5x 10.000    | None| Calibration Study |2600;G1,B0,T-10| 
 +|  20231221T14  | 5x 50.000    | None| Calibration Study |2600;G1,B0,T-10| 
 +|  20231221T14  | 5x 100.000   | None| Calibration Study |2600;G1,B0,T-10| 
 +|  20231221T14  | 5x 1 000.000 | None| Calibration Study |2600;G1,B0,T-10| 
 +|  20231221T14  | 5x 5 000.000 | None| Calibration Study |2600;G1,B0,T-10| 
 +|  20231221T14  | 5x 10 000.000| None| Calibration Study |2600;G1,B0,T-10| 
 +|  20231221T14  | 5x 50 000.000| None| Calibration Study |2600;G1,B0,T-10|
  
 =====Log===== =====Log=====
Line 36: Line 71:
           - Going to wait a few more minutes and repeat to see if it decreases           - Going to wait a few more minutes and repeat to see if it decreases
           - CCD-TEMP did get to -10C. Adjusting understanding of TargetTemp in SC (it seems to be degrees C)           - CCD-TEMP did get to -10C. Adjusting understanding of TargetTemp in SC (it seems to be degrees C)
-      - With gain of 0, brightness of 0, target temp at 10C +      - With gain of 0, brightness of 0, target temp at -10C 
-          - Took 10 frames each at 0.032ms, 0.1ms, 0.5ms, 1ms, 5ms, 10ms, 50ms, 100ms, 500ms, 1000ms, 5000ms, 10 000ms, 50 000ms+          - Took 5 frames each at 0.032ms, 0.1ms, 0.5ms, 1ms, 5ms, 10ms, 50ms, 100ms, 500ms, 1000ms, 5000ms, 10 000ms, 50 000ms 
 +          - Checked CCD-TEMP field of final frame between each set, only proceeded when reported at between -10C and -7C 
 +          - Lul SharpCap reports real-time temperature and target at bottom of GUI 
 +      - With gain of 0, brightness of 0, target temp at 0C 
 +          - Took 5 frames each at 0.032ms, 0.1ms, 0.5ms, 1ms, 5ms, 10ms, 50ms, 100ms, 500ms, 1000ms, 5000ms, 10 000ms, 50 000ms 
 +      - With gain of 1, brightness of 0, target temp at -10C 
 +          - Took 5 frames each at 0.032ms, 0.1ms, 0.5ms, 1ms, 5ms, 10ms, 50ms, 100ms, 500ms, 1000ms, 5000ms, 10 000ms, 50 000ms 
 +      - With gain of 1, brightness of 0, target temp at 0C 
 +          - Opened box a bit bc cooler was struggling to keep temperature 
 +          - Took 5 frames each at 0.032ms, 0.1ms, 0.5ms, 1ms, 5ms, 10ms, 50ms, 100ms, 500ms, 1000ms, 5000ms, 10 000ms, 50 000ms 
 +      - With gain of 5, brightness of 0, target temp at 0C 
 +          - Took 5 frames each at 0.032ms, 0.1ms, 0.5ms, 1ms, 5ms, 10ms, 50ms, 100ms, 500ms, 1000ms, 5000ms, 10 000ms, 50 000ms 
 +      - With gain of 10, brightness of 0, target temp at 0C 
 +          - Took 5 frames each at 0.032ms, 0.1ms, 0.5ms, 1ms, 5ms, 10ms, 50ms, 100ms, 500ms, 1000ms, 5000ms, 10 000ms, 50 000ms 
 +      - With gain of 50, brightness of 0, target temp at 0C 
 +          - Took 5 frames each at 0.032ms, 0.1ms, 0.5ms, 1ms, 5ms, 10ms, 50ms, 100ms, 500ms, 1000ms, 5000ms, 10 000ms, 50 000ms 
 +      - With gain of 100, brightness of 0, target temp at 0C 
 +          - Took 5 frames each at 0.032ms, 0.1ms, 0.5ms, 1ms, 5ms, 10ms, 50ms, 100ms, 500ms, 1000ms, 5000ms, 10 000ms 
 +      - With gain of 150, brightness of 0, target temp at 0C 
 +          - Took 5 frames each at 0.032ms, 0.1ms, 0.5ms, 1ms, 5ms, 10ms, 50ms, 100ms, 500ms, 1000ms, 5000ms, 10 000ms 
 + 
 +  - This took SO LONG. I need to figure out to use the sequencer in sharpCap. I saw that I could likely use the Deep Sky planner, but it only let tenths of a second stand for exposure times. This makes sense for DSO sequencing. There may be a way to get around it. ALSO I may not need this ridiculously short exposure time to suss-out the GAIN and BIAS levels. 
 + 
 +  - Ran the sequencer for the ASI 432 with gain levels 0 and 25, but only the following exposure times 
 +      - 0.1,0.5,1,2,3,4,5,7.5,10,15,20 
 +      - Saved this as calibrationTestSequence in SharpCap Folder in Z Drive. 
 +  - Synced Data to normal gDrive folder 
 +  - LEFT ASI2600 AND ASI432 in control room 
 +  - These will obv need to be reattached.
  